Above-ground ram and articulated arm gate motors

Above-ground linear 24 V ram motors cost €1,800 to €2,850 fitted onto existing sound gates. Deep stone or brick piers with more than 200 mm hinge setback require articulated cranked arms (€2,100 to €3,200 fitted), while heavy solid-infill gates in exposed sites favour hydraulic rams (€2,450 to €3,600).

Clear of floodwater, straightforward to service and matched precisely to pier setback geometry and Irish wind loading.

Free, no obligation. One local installer prices it, not five.

  • €1,800–€2,85024 V linear ram kit, fitted
  • €2,100–€3,200articulated arms, deep piers
  • €2,450–€3,600hydraulic ram pair, fitted
  • >200 mmsetback requiring articulated arm
Painted steel solid-bottom double entrance gates mounted onto a deep brick and rendered masonry pier

Why the pier 'C' dimension chooses the motor for you

Installers measure the distance from the centre of the gate hinge pin straight back to the inner edge of the masonry pier (known as the 'C' dimension). On slim steel posts or flush brick piers under 150 mm, a straight telescopic linear ram achieves smooth geometric leverage. Once a dressed stone or wide rendered Irish pier pushes the hinge more than 200 mm behind the rear face, a straight ram either collides with the stonework or stalls near closed position. Articulated double-jointed arms reach neatly around thick piers up to 350 mm to 450 mm deep without cutting notches out of limestone.

Linear 24 V ram

Fitted retrofit range
€1,800–€2,850
Max pier setback ('C')
Up to 150–200 mm
Wind / solid-leaf duty
Light to medium infill
Storm battery backup
Plug-in 24 V pack available

Articulated cranked arm

Fitted retrofit range
€2,100–€3,200
Max pier setback ('C')
Up to 350–450 mm
Wind / solid-leaf duty
Medium leaves on thick piers
Storm battery backup
Plug-in 24 V pack available

Hydraulic linear ram

Fitted retrofit range
€2,450–€3,600
Max pier setback ('C')
Up to 150–200 mm
Wind / solid-leaf duty
Heavy solid timber & coastal gales
Storm battery backup
Manual key release (230 V AC)

Price my gate system

Four taps show your Irish system price before we ask for a phone number. One local automation installer rings you, not five.

Above-ground ram or articulated arm motors, automating existing gates, remotes only (mains power ready): €1,800 to €3,200, supplied, fitted and safety tested.

Step 1 of 5

Which gate automation system?

Pick the closest match. The installer inspects piers, drainage and hinges on site.

How this system price is worked out

The guide reflects typical Irish supply-and-fit rates for that motor kit, gate scope, access-control hardware and power-supply setup. Base automation figures include motors, control enclosure, dual safety photocells, manual override keys, two handsets and EN 12453 impact force testing. Rock breaking in trenches, rebuilding unstable stone piers, long rural cable runs over 35 m and bespoke sliding ground beams are itemised after an on-site survey. Confirm on the written quote whether VAT is applied at 13.5% or 23% under Revenue rules.

Bracket height, solid infill wind load and electric locks

  • Mount onto a structural horizontal transom. Rams exert huge thrust at bracket bolts; hollow timber slats or thin sheet steel tear loose without a reinforced cross-rail.
  • Fit an electric floor lock on leaves wider than 2.5 m. Locks both leaves dead against the central stop so winter storms cannot strip worm-drive gears.
  • Check shear gaps behind articulated elbows. Any pinch point where the folding arm closes against the pier needs safe clearance or a resistive safety edge under EN 12453.
  • Zero pit digging required. Because surface motors bolt cleanly above ground, there is zero risk of flooded clay boxes and servicing takes half the time.

Common questions on automated gate systems

What motor works on 500 mm wide stone piers?

When the hinge pin sits more than 200 mm from the inside face of the pier, choose articulated cranked-arm motors (€2,100 to €3,200 fitted) or concealed underground boxes.

Are above-ground ram motors cheaper to maintain than underground boxes?

Yes. Every seal, limit switch and screw jack sits out of standing rainwater and can be inspected or replaced without unhanging heavy gate leaves.

Can linear rams automate solid boarded wooden gates?

Yes on sheltered drives up to 3.5 m total width when paired with a central electric lock. On exposed Atlantic hills or heavier hardwood pairs, step up to hydraulic rams.

Do ram motors work if my driveway slopes uphill?

Slightly sloped drives can sometimes be cleared using specialist angled hinge geometry, though steep upward drives over 120 mm rise are far better served by an electric sliding gate.

All gate automation guides and counties

Heavy black iron entrance gate hung from dressed cut-stone piers beside a wet flagstone lane

Check your gate automation price before anyone calls

Select the motor system, gate scope and intercom or power status. When you request a site survey, your outline goes to a single automation installer in your county.